2Thermostats
- Are essential for operating the foil or cable
- Gives accurate temperature control - you set the temperature to suit the plant's needs.
- These are factory fitted into heating foil or cable
- Water resistant enclosures are essential if used near water spray to avoid water ingress to electrical components.
DIGITAL THERMOSTAT (THDW)
- Range: minus 0°C to plus 70° C
- LCD screen/ press button control
- NTC probe sensor
- Probe length 2.0m
- Comes with Mounting Plate
Technical Settings:
This thermostat is pre programed at the factory, therefore the function settings are already set and do not need to set them. However if you need to reset the functions follow the Function Menu Chart below using the column in Red text for Heating purposes.
How to switch on and off:
In the off status, press POWER to switch on
In the on status, press POWER button for 5 seconds to switch off the thermostat
Indicator light description
WORK light indicator: means is in working status, on means work, flash means delay, Off means not working.
SET light indicator: means set status, on means work, off means not working
How to change the temperature setting:
Press SET for one second (you will see the current set temperature displayed)
Use UP or DOWN to adjust the temperature you require
After adjustment press SET for 3 seconds to save
How to reset the function settings to default settings use the Function Menu table below:
Press SET for 3 seconds (set indicator is on), this allows you to enter the main menu.
Follow the steps in the Function Menu chart below, entering the values listed in the Heating Equipment setting (marked in red).
For HC: use UP or DOWN button to choose H (for heat setting)
After adjustment press SET to the next parameter and continue through the list codes using the same procedure.
Or to cycle through the settings: press SET to move to the next code setting.
Function menu table
Code
|
Function
|
Setting range
|
Default
|
Settings for: Heating equipment & Foil Mat
(pre set at factory-no need to set)
|
HC
|
mode
|
C: cool, H: heat
|
C
|
H
|
d
|
differential
|
1~15
|
3
|
2
|
LS
|
Low temp
|
-40~setting temp
|
-40
|
0
|
HS
|
High temp
|
Setting temp~99
|
99
|
+30
|
CA
|
Calibration
|
-5~5
|
0
|
0
|
Pt
|
Delay time
|
0~15
|
3
|
0
|
Error Codes
Code
|
Reason
|
Troubleshooting
|
HH
|
Sensor probe short circuit or exceeds the highest measuring temperature
|
Replace probe sensor
|
LL
|
Sensor probe open circuit or exceeds the lowest measuring temperature
|
Replace probe sensor
|
-
|
Sensor probe is disconnected
|
Connect the sensor probe to the correct terminals
|
EE
|
Sensor probe is faulty
|
Replace probe sensor
|
Alarm sound
|
Sensor probe is faulty
|
Replace probe sensor
|
Incorrect temperature reading
|
Sensor probe is faulty
|
Replace probe sensor
|