THDW Digital Thermostat (in water resistant enclosure)

Thermostats

  • Are essential for operating the foil or cable
  • Gives accurate temperature control - you set the temperature to suit the plant's needs.
  • These are factory fitted into heating foil or cable
  • Water resistant enclosures are essential if used near water spray to avoid water ingress to electrical components.

    DIGITAL THERMOSTAT (THDW)

    • Range: minus 0°C to plus 70° C 
    • LCD screen/ press button control
    • NTC probe sensor
    • Probe length 2.0m
    • Comes with Mounting Plate 

    Technical Settings:

    This thermostat is pre programed at the factory, therefore the function settings are already set and do not need to set them. However if you need to reset the functions follow the Function Menu Chart below using the column in Red text for Heating purposes.

    How to switch on and off:

    In the off status, press POWER to switch on

    In the on status, press POWER button for 5 seconds to switch off the thermostat

    Indicator light description

    WORK light indicator: means is in working status, on means work, flash means delay, Off means not working.

    SET light indicator: means set status, on means work, off means not working

    How to change the temperature setting:

    Press SET for one second (you will see the current set temperature displayed)

    Use UP or DOWN to adjust the temperature you require

    After adjustment press SET for 3 seconds to save

    How to reset the function settings to default settings use the Function Menu table below:

    Press SET for 3 seconds (set indicator is on), this allows you to enter the main menu.

    Follow the steps in the Function Menu chart below, entering the values listed in the Heating Equipment setting (marked in red).

    For HC: use UP or DOWN button to choose H (for heat setting)

    After adjustment press SET to the next parameter and continue through the list codes using the same procedure.

    Or to cycle through the settings: press SET to move to the next code setting.

    Function menu table

    Code

    Function

    Setting range

    Default

    Settings for: Heating equipment & Foil Mat

    (pre set at factory-no need to set)

    HC

    mode

    C: cool, H: heat

    C

    H

    d

    differential

    1~15

    3

    1

    LS

    Low temp

    -40~setting temp

    -40

    0

    HS

    High temp

    Setting temp~99

    99

    +30

    CA

    Calibration

    -5~5

    0

    0

    Pt

    Delay time

    0~15

    3

    0

     

    Error Codes

    Code

    Reason

    Troubleshooting

    HH

    Sensor probe short circuit or exceeds the highest measuring temperature

    Replace probe sensor

    LL

    Sensor probe open circuit or exceeds the lowest measuring temperature

    Replace probe sensor

    -

    Sensor probe is disconnected

    Connect the sensor probe to the correct terminals

    EE

    Sensor probe is faulty

    Replace probe sensor

    Alarm sound

    Sensor probe is faulty

    Replace probe sensor

    Incorrect temperature reading

    Sensor probe is faulty

    Replace probe sensor

     